Podobne

[ Pobierz całość w formacie PDF ]

[9][3][*][#] Restores default settings (factory settings).
[9][9][*][#] Switch the dialer to Downloading Mode, one the device enters Downloading Mode it will leave it after power on/off or remote
command from downloading computer. The communication between dialer and computer requires UT-1 interface cable.
[*][#] Exit from the installer programming mode, when you enter the command, the dialer performs the restart procedure and
enters standard operation mode.
- 14 -
D09 v4.0 EN.doc Rev. A 2008-11-18
DEFAULT (Factory) VALUES
The default values of the dialer s memory are restored each time you perform the "EEPROM RESET".
Telephone
Status Reprogramming
Number
#1 Not programmed Enabled
#2 Not programmed Enabled
#3 Not programmed Enabled
#4 Not programmed Enabled
#5 Not programmed Enabled
#6 Not programmed Enabled
#7 Not programmed Enabled
#8 Not programmed Enabled
First telephone number to pager station: Not programmed
Second telephone number to pager station: Not programmed
Telephone Line Options
" Wait 4 seconds for dial tone
" Wait for dial tone
" Pulse dialing system
" Wait for phone pick-up
" [KU0] usage via DTMF (Tone Remote Control feature) disabled
" Send Alarm Voice Message two times to each telephone number
" Answer incoming calls after 4 rings
" Double Call Timer disabled
Text message to a Pager station: Not programmed
Codes:
CODE DIGITS REPROGRAMMING
[KU0] [0000] Enabled
[KU1] [1111] Enabled
[KU2] [2222] Enabled
[KU3] [3333] Enabled
[KU4] [4444] Enabled
[KU5] [5555] Enabled
[KU6] [6666] Enabled
[KU7] [7777] Enabled
[KU8] [8888] Enabled
[KU9] [9999] Enabled
[KI] [1234]
TIME DELAYS
Delay before arming : 0 sec.
Pause after alarm action : 0 min.
Delay before dialer will start alarm action : 0 sec.
SYSTEM OPTIONS
Do not disable keypad after three unsuccessful attempts of entering code
Do not disable telephone line voltage detection
Enabled clock re-programming
Enable voice alarm message recording
Four dialing attempts for each telephone number
Voice Alarm Message repeated four times
Auto-Arming disabled
Monitoring Stations
Communication Mode : Communication to AMS disabled
Telephone number to AMS1 : Not programmed
Account number to AMS1 : 000
Format of transmission to AMS1 : SILENT KNIGHT/ADEMCO SLOW
Telephone number to AMS2 : Not programmed
Account number to AMS2 : 000
Format of transmission to AMS2 : SILENT KNIGHT/ADEMCO SLOW
Reporting Codes
All reprting codes set to [00]
Test Transmission Time :00:00
Voice Messages
Voice Alarm Message : Not recorded
Dialer Armed Message : Not recorded
Dialer Disarmed Message : Not recorded
- 15 -
D09 v4.0 EN.doc Rev. A 2008-11-18
Event s History
Time of telephone line voltage loss : Empty
Time of last entry to armed mode : Empty
Time of last alarm action : Empty
Time of AC voltage loss : Empty
TECHNICAL SPECIFICATION
Power supply voltage 11..15 Vdc
Supply current max. 100mA
Dialing system DTMF/PULSE
Operating temperature range 0-50 °C
- 16 -
D09 v4.0 EN.doc Rev. A 2008-11-18
DRAWINGS
NOTE:
Do not tune potentiometer on electronic module
CONDENSER
MICROPHONE
JP1
JP2
Dial 09/07 v3.0
www.roger.pl
JP1 - Download Mode
JP2 - Memory Reset
MINI-JACK
HEADPHONE
OUTPUT
TAMPER T-1 TIP EARTH GND PGM1 A4 A2
DIAMETER 3,5 mm
R-1 RING +12V PGM2 A3 A1
TAMPER DELAY
A1
CONTACTS ALARM INPUT
TELEPHONE OR OTHER
INSTANT ALARM INPUT
DEVICES CONNECTED
A2
( H24 TYPE )
TO TELEPHONE LINE
CONTROL
TELEPHONE
A3
INPUT
LINE
A4 RESERVED
TELEPHONE LINE
VOLTAGE LOSS
SIGNALLING OUTPUT
ALARM SIGNALLING
OUTPUT
DIALER POWER SUPLY
11 & 15 VDC
Connection diagram of D07M v3.0
PGM1/PGM2
V+ (SUPPLY  PLUS )
Max. 1A/18V
5k6
LOGIC
CIRCUIT
LOGIC
100k
CIRCUIT
A1/A2/A3/A4
GND GND
A1/A2/A3/A4 ALARM INPUT STRUCTURE PGM1, PGM2 OUTPUT STRUCTURE
- 17 -
JP1
uP Reset
1
PGM2
PGM1
D09 v4.0 EN.doc Rev. A 2008-11-18
- 18 -
D09 v4.0 EN.doc Rev. A 2008-11-18
1
- 19 - [ Pobierz całość w formacie PDF ]




Powered by MyScript